Arctic Heat Pump 025ZA/B - 11KW
Heats/Cools
Air to Water Heat pump for pools, hot tubs and spas
Requires SIN or Tax ID for shipping to USA
025ZA/B Heat/Chill Heat Pump
Chiller and Heater in one unit
While hot tub users most often reference the heating requirements, the Arctic Heat Pump is also a chiller if need. That’s right...It can heat and cool based on a simple controller selection. Ideal for hot climates that need a retreat from the hot summer heat! A cold water plunge is a must for Sauna owners. Now you can quickly change your hot tub to a cold plunge tub! Cold water therapy has many health benefits and is growing in popularity in North America as we discover what the Nordic Culture has practiced for centuries.
Excessively hot swimming pools cause problems with the chemical imbalance and can quickly become full of algae if not properly monitored. Chlorine evaporates as the water temperature rises. In areas such as California, Texas, Arizona and Florida, the hot summer temperatures can be difficult for pool owners. The Arctic Pool & Spa Heat Pumps allows owners to reduce the temperatures back down to proper levels. By Chilling your pool you can get reprieve from hot summer heat waves, when the temperature drops, the Arctic Heat Pump will switch back to heating mode.
Heating & Cooling
The Arctic 025ZA/B Heat Pumps works down to -4°F (-20°C). This air to water heat source is the most efficient cold weather heat pump on the market. Heats and cools with over 80% savings of traditional heating equipment. This unit is cable of producing up to 11 Kw or 37,500 BTU of heat energy. No other pool or spa heat pump on the market will outperform the Arctic 025ZA/B in colder weather. This allows you to open your pool earlier and close it later. It is also ideal for energy savings for spas and hot tubs. Working up to 104 F even in 20 F conditions! The Arctic 025ZA/B is great heat pump for most pools.
Features
Three Modes: Heating, Cooling, and Auto
Includes Heat Pump Digital Controller: Easy to operate LCD controller. Set the water temperature and other parameters as you need, and monitor unit operation.
|
WiFi Remote Control Option: Control your Arctic Heat Pump and know the current operation of the heat pump at any time via your phone. |
Double Rotor DC Inverter Compressor
|
Operating Temperature Range -4°F (-20°C) to 113°F (45°C)
|
Spiral Titanium Heat Exchanger |
Ultra Quiet DC Brushless Fan Motor
|
Sound Insulation |
High Efficiency Fin Heat Exchanger |
• Heat Pump for hot tubs, spas and smaller pools or swim spas
• Easy to install with no refrigeration mechanic needed
• Vibration pads included
• Drain pan and compressor low temp protection
• Hot gas defrost
• Drain Pan Freeze Protection for cold weather
• TUV Rheinland certified for installation in North America
How it works - The Arctic Heat Pump harness the energy found in the air. By using an oversized evaporator the energy is removed and transferred to the refrigerant. A compressor compresses the gas causing its temperature to increase. The hot gas then passes through a titanium pool heat exchanger where it is transferred directly to the pool or spa water. In cooling mode the unit reverses direction and chills the pool water by removing the heat from the titanium heat exchanger and discharging it out the evaporator.
The unit consumes electricity at a rate of only 1/3 to 1/5 of the heating capacity that it produces. The result is energy savings as high as 80% compared to traditional electric or gas pool or spa heaters. Built in hot gas defrost and drain pan/compressor freeze protection for cold weather performance.
Example Layout - Pool or Spa Heat Pump
Specifications
• 1.5" water connections
• Max Amps 10.8
• 220-240 VAC
• Output 11 Kw (37,500 BTU)
• Weight 212 LBS (96 Kg)
• Flow rate 24 GPM (pool pump sold separately)
• 47" long x 21" wide x 29" tall
• 1 year parts warranty - 2 year compressor warranty (Extended Warranty Available)
Air to Water Swimming Pool & Spa Heat Pump
Model |
ARCTIC |
015ZA/B |
25ZA/B |
040ZA/B |
060ZA/B |
Power Supply |
V/PH/Hz |
220/1/50 (60) |
220/1/50 (60) |
220/1/50 (60) |
220/1/50 (60) |
Heating Capacity
Ranger |
kW |
1.3~5.2 |
2.75~11 |
4.38~17.5 |
6.45~25.8 |
BTU/h |
4436~17742 |
9383~37532 |
14928~59710 |
22007~88030 |
COP Ranger |
W/W |
3.6~13 |
3.6~13 |
3.6~13 |
3.6~13 |
Heating Capacity (1) |
kW |
5.2 |
11.0 |
17.5 |
25.8 |
BTU/h |
17742 |
37532 |
59710 |
88030 |
COP (1) A:30/W:28 |
W/W |
6.2 |
6.2 |
6.2 |
6.2 |
Input Power (1) |
kW |
0.84 |
1.77 |
2.82 |
4.16 |
Input Current (1) |
A |
3.8 |
8.1 |
12.8 |
18.9 |
Heating Capacity (2) |
kW |
5.2 |
11.0 |
17.5 |
25.8 |
BTU/h |
17742 |
37532 |
59710 |
88030 |
COP (2) A:24/W:28 |
W/W |
5.60 |
5.60 |
5.60 |
5.60 |
Input Power (2) |
kW |
0.93 |
1.96 |
3.13 |
4.61 |
Input Current (2) |
A |
4.2 |
8.9 |
14.2 |
20.9 |
Heating Capacity (3) |
kW |
5.2 |
11.0 |
17.5 |
25.8 |
BTU/h |
17742 |
37532 |
59710 |
88030 |
COP (3) A:15/W:28 |
W/W |
4.8 |
4.8 |
4.8 |
4.8 |
Input Power (3) |
kW |
1.08 |
2.29 |
3.65 |
5.38 |
Input Current (3) |
A |
4.9 |
10.4 |
16.6 |
24.4 |
Heating Capacity (4) |
kW |
4.8 |
10.0 |
16.7 |
23.5 |
BTU/h |
16378 |
34120 |
56980 |
80182 |
COP (4) A:7/W:28 |
W/W |
4.2 |
4.2 |
4.2 |
4.2 |
Input Power (4) |
kW |
1.14 |
2.38 |
3.98 |
5.60 |
Input Current (4) |
A |
5.2 |
10.8 |
18.1 |
25.4 |
Heating Capacity (5) |
kW |
4.3 |
9.2 |
14.4 |
21.0 |
BTU/h |
14672 |
31390 |
49133 |
71652 |
COP (5) A:0/W:28 |
W/W |
3.72 |
3.72 |
3.72 |
3.72 |
Input Power (5) |
kW |
1.16 |
2.47 |
3.87 |
5.65 |
Input Current (5) |
A |
5.3 |
11.2 |
17.6 |
25.7 |
Heating Capacity (6) |
kW |
3.6 |
7.5 |
12.0 |
18.0 |
BTU/h |
12283 |
25590 |
40944 |
61416 |
COP (6) A:-7/W:28 |
W/W |
3.16 |
3.16 |
3.16 |
3.16 |
Input Power (6) |
kW |
1.14 |
2.37 |
3.80 |
5.70 |
Input Current (6) |
A |
5.2 |
10.8 |
17.3 |
25.9 |
Compressor |
|
Rotary |
TWIN Rotary |
TWIN Rotary |
TWIN Rotary |
Compressor Qty |
|
1 |
1 |
1 |
1 |
Fan Qty |
|
1 |
1 |
1 |
1 |
Noise |
dB(A) |
48 |
52 |
54 |
54 |
Water Outlet/Water Inlet |
inch |
1–1/2" |
1–1/2" |
1–1/2" |
1–1/2" |
Water Flow Volume |
GPM |
16 |
24 |
32.5 |
33 |
Water Pressure Drop |
PSI |
1.7 |
2.2 |
2.2 |
2.3 |
Fan Direction |
|
horizontal |
horizontal |
horizontal |
horizontal |
Refrigerant Type |
|
R410A |
R410A |
R410A |
R410A |
Unit Net Dimensions (L/M/H) |
mm |
930/360/550 |
1115/470/700 |
1115/470/945 |
1195/470/1285 |
Unit Shipping Dimensions (L/M/H) |
mm |
1035/395/585 |
1205/525/725 |
1205/525/975 |
1285/525/1315 |
Net Weight |
kg |
55 |
90 |
108 |
121 |
Shipping Weight |
kg |
58 |
96 |
116 |
131 |
Note:
(1) Heating:Outdoor air temp: 30°C/24°C Outlet water temp: 28°C, Input water temp: 26°C;
(2) Heating:Outdoor air temp: 24°C/19°C Outlet water temp: 28°C, Input water temp: 26°C;
(3) Heating:Outdoor air temp: 15°C/12°C Outlet water temp: 28°C, Input water temp: 26°C;
(4) Heating:Outdoor air temp: 7°C/6°C Outlet water temp: 28°C, Input water temp: 26°C;
(5) Heating:Outdoor air temp: 0°C/-°C Outlet water temp: 28°C, Input water temp: 26°C;
(6) Heating:Outdoor air temp: -7°C/-°C Outlet water temp: 28°C, Input water temp: 26°C; |
No taxes to US residence!
Please allow 4-6 days for shipping via UPS Ground to USA or Canada. You will be emailed a tracking number to the email address you provide us. Expedited Shipping services are available!
Your #1 Hot Tub Parts Replacement Store!